Concept of a Meridian One data hall with sealed cooling pipework, navy server racks and warm timber finishes

Meridian One / Water & Cooling

Cooled.
Recirculated.
Reused.

Our proposed cooling system keeps coolant moving in sealed loops, carrying heat away from the servers and releasing it to the air.

Designed around recirculation.Concept visualisation · Indicative only

The annual estimate

Putting water
in perspective.

For the proposed full campus, the current estimate for normal operations is approximately:

1.3 million

litres per year 1,300 m³

Mainly staff and welfare. This is a provisional planning estimate, with the final water balance to be confirmed. Initial system fills, fire-water storage and major maintenance refills are assessed separately.

42%

About 42% of one Olympic-size swimming pool, per year.

Annual estimate compared with one swimming pool The shaded 41.6 per cent represents 1.3 million litres. The whole pool represents 3.125 million litres. 1.3m litres
Estimated annual water demand
Comparison pool: 50 m × 25 m × 2.5 m = 3.125 million litres. The annual estimate equals 41.6%, rounded to 42%.

How it works

Two loops.
One continuous cycle.

Warm coolant Cooled coolant

Water-based coolant absorbs heat at the servers. A heat exchanger passes that heat into a separate facility loop. Outside, dry coolers release the heat into the air.

Two separate sealed cooling loops Warm server coolant flows right to the heat exchanger; cooled server coolant returns left to the servers. In a separate circuit, warm facility coolant flows right from the exchanger to the dry coolers, and cooled facility coolant returns left. The two fluids do not mix. Server loopFacility loop Heat travels outCooled fluid returns Heat travels outCooled fluid returns Server cold platesCapture chip heat Heat exchangerFluids stay separate Outdoor dry coolersHeat released to air Simplified proposed arrangement · Heat crosses the exchanger; the two coolant circuits remain separate. Two separate cooling loops The server loop circulates between server cold plates and a heat exchanger. The facility loop circulates between the heat exchanger and outdoor dry coolers. Warm coolant travels down the right-hand paths; cooled coolant returns up the left-hand paths. Fluids stay separate at the exchanger. Server cold platesCapture chip heat Server loopCooled fluid returns Heat exchangerFluids stay separate Facility loopCooled fluid returns Outdoor dry coolersHeat released to air Simplified proposed arrangement
The cooled coolant returns to the servers, ready to absorb heat again. The same fluid circulates repeatedly; it is not replaced on each cycle.

Capture the heat

Cold plates bring coolant close to the chips. It carries heat back to a coolant distribution unit, where the heat exchanger connects the two loops thermally.

Keep the water contained

Fans move outdoor air across sealed dry-cooler coils. The proposed design uses no cooling towers, water spray or adiabatic assist.

Recirculate and monitor

Temperature, pressure, flow and fluid quality need monitoring. Initial filling and replenishment after maintenance or losses still require water.

Concept of outdoor dry-cooler fans beside a landscaped Meridian One campus building with sage cladding and warm timber

Dry heat rejection

Heat to the air.
Coolant in the loop.

Recirculation keeps the coolant in use. Dry coolers are the part of the proposed system designed to avoid water evaporation for heat rejection.

Detailed design must confirm performance on the hottest days without switching to a wet cooling mode.

Proposed cooling approachConcept visualisation · Equipment and layout indicative
Meridian One Water + Cooling: How it worksWatch the film

Watch the explainer

See the cycle.
Understand the thinking.

A closer look at Meridian One’s proposed water and cooling approach.

Visit our YouTube channel

A little more detail

Clear assumptions.
Considered design.

Ask the Meridian One team

What does the annual estimate include?

The latest project water and cooling explainer gives approximately 1,300 m³ per year for normal operations, mainly staff and welfare, across the proposed five-phase campus on a 100 MW total-import design basis. This is a planning estimate, not measured consumption or a guaranteed maximum. Cooling make-up, staff numbers and the operating calendar need confirmation in the final water balance. One-off fills, fire-water storage and exceptional drain-down or refill events are assessed separately.

Does closed-loop mean no water at all?

No. The loops need an initial charge of coolant and may need replenishment after maintenance or losses. Staff and welfare facilities also need water. The proposed combination of sealed loops and dry heat rejection avoids routine evaporative cooling; closed-loop circulation alone would not establish that.

How is the swimming-pool comparison calculated?

For this comparison, an Olympic-size pool is 50 metres long, 25 metres wide and 2.5 metres deep: 3,125 m³. Dividing the annual estimate of 1,300 m³ by 3,125 m³ gives 41.6%, rounded to 42%. This compares a year’s estimated fresh-water demand with one pool’s stored volume.